Brivo Onair Release Notes 11.19

8/30/2017

This release includes additional ACS300 support for Allegion NDE gateways.

Improvements

  • When configuring a ACS300 controller, the OSDP port now supports Allegion NDE gateways.
    • The ACS300 panel has one OSDP definable port (Port 1):
      • Operation Mode – Port 1 can be set to either Allegion RSI or OSDP Reader. Since Allegion NDE devices and OSDP use different protocols, you need to select the correct operation mode. For example, you cannot set the Operation Mode to Allegion RSI and connect an OSDP reader.
      • Baud Rate – This is the speed at which the information is transferred over the line.
      • Error Detection Method – Allows you to select either Checksum or Cyclic Redundancy Check (CRC) as the method you use for error detection.
      • Peripheral Device Address – Since RS485 is a bus and several devices can coexist on the same bus, there needs to be a way that different devices on the bus can be sent specific messages. Addressing solves this problem.
×
×
×